Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
J. oral res. (Impresa) ; 11(6): 1-10, nov. 3, 2022. ilus, tab
Article in English | LILACS | ID: biblio-1437657

ABSTRACT

Aim: To assess the effect of different mechanical surface treatments on flexural strength of repaired denture base. Material and Methods: Sixty bar-shaped specimens of heat-polymerized acrylic resin were fabricated, and divided into six groups (n=10). All specimens, except the positive control group (group PC), were sectioned into halves to create a 1-mm clearance. A negative control group with no surface treatment (group NC) was also considered. Other groups underwent different surface treatments: group Laser; treated with erbium: yttrium-aluminum-garnet (Er:YAG) laser, group APA; airborne-particle abrasion (APA), group APA plus Laser; a combination of laser and APA, and group Bur; bur grinding. After measuring surface roughness (Ra) with a profilometer, all sectioned specimens were repaired by auto-polymerizing acrylic resin, and thermocycled afterward. Three-point bending test was performed by a universal testing machine. Data were statistically analyzed (α=0.05). Results: The mean surface roughness of all experimental groups were significantly higher than that of group NC (p<0.05). The mean flexural strength of all groups was significantly lower than that of group PC (p<0.05). Group B had significantly higher flexural strength than the other surface-treated groups (p<0.05). Group Laser had significantly higher flexural strength than groups APA (p=0.043) and APA plus Laser (p=0.023). No significant difference was found between groups APA and APA plus Laser (p=0.684). Conclusion: All surface treatments increased the surface roughness and flexural strength compared with the untreated group. The highest flexural strength was observed in specimens treated by bur grinding and then laser, however, it was still significantly lower than intact specimens.


Objetivo: Evaluar el efecto de diferentes tratamientos superficiales mecánicos sobre la resistencia a la flexión de la base de la prótesis reparada. Material y Métodos: Se fabricaron sesenta especímenes en forma de barra de resina acrílica termo-polimerizada y se dividieron en seis grupos (n=10). Todas las muestras, excepto el grupo de control positivo (grupo PC), se seccionaron en mitades para crear un espacio libre de 1 mm. También se consideró un grupo de control negativo sin tratamiento superficial (grupo NC). Otros grupos se sometieron a diferentes tratamientos superficiales: grupo Láser; tratados con láser de erbio: itrio-aluminio-granate (Er:YAG), grupo APA; abrasión por partículas en el aire (APA), grupo APA más láser; una combinación de láser y APA, y grupo Bur; molienda de fresas. Después de medir la rugosidad de la superficie (Ra) con un perfilómetro, todas las muestras seccionadas se repararon con resina acrílica de autopolimerización y se sometieron a termociclado. La prueba de flexión de tres puntos se realizó con una máquina de prueba universal. Los datos se analizaron estadísticamente (α=0,05). Resultados: La rugosidad superficial media de todos los grupos experimentales fue significativamente mayor que la del grupo NC (p<0,05). La resistencia media a la flexión de todos los grupos fue significativamente menor que la del grupo PC (p<0,05). El grupo B tenía una resistencia a la flexión significativamente mayor que los otros grupos tratados en la superficie (p<0,05). El grupo Láser tuvo una resistencia a la flexión significativamente mayor que los grupos APA (p=0,043) y APA más Láser (p=0,023). No se encontró diferencia significativa entre los grupos APA y APA más Láser (p=0,684). Conclusión: Todos los tratamientos superficiales aumentan la rugosidad de la superficie y la resistencia a la flexión en comparación con el grupo sin tratar. La resistencia a la flexión más alta se observó en las muestras tratadas con fresado y luego con láser; sin embargo, aún era significativamente más baja que las muestras intactas.


Subject(s)
Humans , Acrylic Resins/chemistry , Denture Repair , Polymethyl Methacrylate/chemistry , Dental Materials/chemistry , Denture Bases , Lasers, Solid-State , Methacrylates/chemistry
2.
Surg. cosmet. dermatol. (Impr.) ; 14: e20220063, jan.-dez. 2022.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1369838

ABSTRACT

A sarcoidose é uma doença granulomatosa sistêmica com envolvimento cutâneo em 10 a 25% dos casos. O quadro cutâneo tem sido frequentemente associado a traumas prévios, incluindo o uso de preenchedores cutâneos. Apresenta-se caso de paciente com placa eritematosa em dorso nasal com 12 meses de evolução e histórico de preenchimentos prévios com PMMA e ácido hialurônico. A biópsia cutânea evidenciou processo inflamatório granulomatoso de padrão epitelióide e células gigantes multinucleadas, características de sarcoidose cutânea. As reações granulomatosas tardias podem estar associadas ao uso de preenchedores, tanto pelo trauma provocado pelas cânulas quanto pelos antígenos dos preenchedores utilizados


Sarcoidosis is a systemic granulomatous disease with skin involvement in 10% to 25% of cases. This skin condition has been associated with previous trauma, including the use of skin fillers. We present the case of a patient with an erythematous plaque on the nasal dorsum with 12 months of evolution and a history of previous facial fillings with polymethylmethacrylate and hyaluronic acid. Skin biopsy showed a granulomatous inflammatory process with an epithelioid pattern and multinucleated giant cells, characteristic of cutaneous sarcoidosis. Sarcoidosis can occasionally manifest without systemic involvement and may be associated with the previous use of long-term tissue fillers

3.
Rev. Col. Bras. Cir ; 49: e20223060, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1422719

ABSTRACT

ABSTRACT Objective: the management of septic metaphyseal nonunions is challenging, with inconsistent outcomes. Antibiotic cement-coated implants have been demonstrated good outcome for diaphyseal infected nonunions, however there is no data in metaphyseal infected nonunions. Methods: fifteen adult patients with septic metaphyseal nonunions of the femur or tibia were treated with antibiotic cement-coated plates. The antibiotic cement-coated plate was prepared with either gentamicin or vancomycin. Outcome measures were infection control, bone healing, return to pre-injury level on daily activities, and quality of life at the last follow-up visit. A p value of <5% was considered significant. Results: Methicillin-susceptible S. aureus was isolated in 53.3% cases. Average postoperative follow-up time was 18 months. Local infection control and radiographic bone healing were adequately achieved in 93.3% patients. No patient presented recurrent symptoms of surgical site infection. Fourteen patients reported to be either able, or on the same level as before injury, with 73.3% reporting no problems in all five dimensions of the EQ-5D-3L. Persistent infection was the only variable associated with a reduced long-term quality of life. Conclusion: antibiotic cement-coated plate is a viable and efficient surgical technique for the definitive management of juxta-articular metaphyseal septic nonunions of the femur and tibia.


RESUMO Introdução: implantes revestidos de cimento com antibiótico vêm demonstrando bons resultados no tratamento da pseudoartrose infectada da diáfise, no entanto seu uso na metáfise dos ossos longos ainda é pouco explorado. Neste estudo relatamos uma série de casos de pseudoartrose infectada da metáfise do fêmur e da tíbia tratados com o uso de placas revestidas de cimento com antibiótico. Métodos: Os antibióticos usados foram gentamicina e/ou vancomicina. Os desfechos analisados na última visita ambulatorial foram controle de infecção, consolidação óssea, retorno às atividades diárias e qualidade de vida. Regressão linear bivariada foi usada para avaliar fatores individuais que afetaram a qualidade de vida dos pacientes. Um valor p<5% foi considerado estatisticamente significativo. Resultados: quinze pacientes adultos foram incluídos no estudo. S. aureus suscetível à meticilina foi isolado em 53,3% dos casos. O tempo médio de acompanhamento pós-operatório foi de 18 meses. Controle local da infecção e consolidação óssea radiográfica foram alcançados em 93,3% dos pacientes. Nenhum paciente apresentou sintomas recorrentes de infecção de sítio cirúrgico. Quatorze pacientes relataram ser capazes, mas não no nível pré-lesional ou no mesmo nível de antes da lesão, com 73,3% relatando nenhum problema em todas as cinco dimensões do EQ-5D-3L. Infecção persistente foi a única variável associada à redução da qualidade de vida a longo prazo. Conclusão: A placa revestida de cimento com antibiótico mostrou-se uma técnica cirúrgica viável e eficiente para o tratamento da pseudoartrose infectada da metáfise do fêmur e da tíbia.

4.
J. bras. nefrol ; 43(2): 288-292, Apr.-June 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1286930

ABSTRACT

Abstract Cosmetic injections of fillers are common plastic surgery procedures worldwide. Polymethylmethacrylate (PMMA) is a filler approved only for minimally invasive procedures in facial tissue and is among the most frequently used injectable substances for cosmetic purposes. Injection of a large volume of PMMA may lead to the development of severe hypercalcemia and chronic kidney damage in a probably underestimated frequency. In such cases, hypercalcemia develops due to a granulomatous foreign body reaction with extrarenal production of calcitriol. In the present report, we describe the cases of two patients who received injections of large volumes of PMMA and developed severe hypercalcemia and advanced chronic kidney disease. These reports highlight the importance of adhering to regulations regarding the use of PMMA and properly informing patients of the possibility of complications before undertaking such procedures.


Resumo Injeções de preenchimento de caráter estético são procedimentos comuns em cirurgia plástica em todo o mundo. O polimetilmetacrilato (PMMA) é um material de preenchimento aprovado apenas para procedimentos minimamente invasivos no tecido facial, e está entre as substâncias injetáveis mais frequentemente usadas para fins estéticos. A injeção de um grande volume de PMMA pode levar ao desenvolvimento de hipercalcemia grave e lesão renal crônica em uma frequência provavelmente subestimada. Nesses casos, a hipercalcemia se desenvolve devido a uma reação granulomatosa de corpo estranho, secundária à produção extrarenal de calcitriol. No presente artigo, descrevemos os casos de dois pacientes que receberam injeções de grandes volumes de PMMA e desenvolveram hipercalcemia grave e doença renal crônica avançada. Esses relatos destacam a importância de seguir as regulamentações sobre o uso do PMMA e informar adequadamente os pacientes sobre a possibilidade de complicações antes de realizar tais procedimentos.


Subject(s)
Humans , Cosmetic Techniques , Renal Insufficiency, Chronic/complications , Hypercalcemia/chemically induced , Calcitriol , Polymethyl Methacrylate/adverse effects
5.
J. oral res. (Impresa) ; 10(2): 1-9, abr. 30, 2021. ilus, tab
Article in English | LILACS | ID: biblio-1381731

ABSTRACT

Objective: To determine the cytotoxicity and effects of graphene oxide (GO) on cellular proliferation of gingival-fibroblasts, pulp-dental cells and human osteoblasts in culture, and to determine the physical, mechanical and biological properties of poly (methyl methacrylate) (PMMA) enriched with GO. Material and Methods: The GO was characterized with SEM. Cytotoxicity and cell proliferation were determined by the MTT bioassay. The physical mechanical tests (flexural strength and elastic modulus) were carried out with a universal testing machine. Sorption and solubility were determined by weighing before and after drying and immersion in water. Porosity was evaluated by visual inspection. Data were analyzed with Student's t-test and Tukey's posthoc ANOVA. Results: The GO has a heterogeneous morphology and a particle size of 66.67±64.76 µm. GO has a slight to no-cytotoxicity (>50-75% viability) at 1-30 days, and at 24 hours incubation of PMMA with GO significantly stimulates osteoblasts (45±8%, p<0.01). The physical and mechanical properties of PMMA with GO increase considerably without altering sorption, solubility and porosity. Conclusion: GO alone or with PMMA has an acceptable biocompatibility, could contribute to cell proliferation, cell regeneration and improve the physical mechanical properties of PMMA.


Objective: To determine the cytotoxicity and effects of graphene oxide (GO) on cellular proliferation of gingival-fibroblasts, pulpdental cells and human osteoblasts in culture, and to determine the physical, mechanical and biological properties of poly (methyl methacrylate) (PMMA) enriched with GO. Material and Methods: T he G O w as c haracterized with SEM. Cytotoxicity and cell proliferation were determined by the MTT bioassay. The physical-mechanical tests (flexural strength and elastic modulus) were carried out with a universal testing machine. Sorption and solubility were determined by weighing before and after drying and immersion in water. Porosity was evaluated by visual inspection. Data were analyzed with Student's t-test and Tukey's post-hoc ANOVA. Results: The GO has a heterogeneous morphology and a particle size of 66.67±64.76 ?m. GO has a slight to no-cytotoxicity (>50-75% viability) at 1-30 days, and at 24 hours incubation of PMMA with GO significantly stimulates osteoblasts (45±8%, p<0.01). The physical and mechanical properties of PMMA with GO increase considerably without altering sorption, solubility and porosity. Conclusion: GO alone or with PMMA has an acceptable biocompatibility, could contribute to cell proliferation, cell regeneration and improve the physical-mechanical properties of PMMA.


Subject(s)
Humans , Biocompatible Materials , Polymethyl Methacrylate/chemistry , Graphite/chemistry , Osteoblasts , Oxides , Regeneration , Biological Assay , Cell Proliferation , Flexural Strength
6.
Arq. odontol ; 57: 236-243, jan.-dez. 2021. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-1348373

ABSTRACT

Objetivo:Avaliar in vitro a atividade de Staphylococcus aureus e Candida albicans em bases de próteses convencionais à base de polimetilmetacrilato de metila com nanopartículas de prata incorporadas a sua composição. Métodos: Foi realizado um estudo experimental laboratorial com resinas acrílicas autopolimerizáveis comercialmente disponíveis, Vipi Flash/VIPI e JET/Clássico. Foram confeccionados 80 corpos de prova, divididos em 16 grupos (n = 5), referentes ao tipo de resina, tratamento (incorporação e imersão na solução de nanopartículas de prata) e microrganismo inoculado. As nanopartículas foram sintetizadas com ácido polimetacrílico, nitrato de prata e irradiadas com luz ultravioleta de baixa potência (~8W) por 6 horas, e as suas concentrações idealizadas pelo método de microdiluição em placas para determinação da concentração mínima inibitória frente aos microrganismos selecionados. Verificou-se ação bactericida e fungicida com concentração inicial de 25% e após fator de diluição 12,5%. Resultados: Houve dificuldade de incorporação das nanopartículas na resina acrílica, que pode decorrer da alteração da proporção 3:1 recomendada pelo fabricante ou pela redução ou inativação da ação da nanopartícula de prata pela interação com o polimetilmetacrilato. VIPI com inclusão de nanopartícula obteve menor aderência de biofilme de Candida albicans. Conclusão:A nanopartícula de prata mostrou-se eficaz na sua ação de controle de Candida albicans e Staphylococcus aureus no método de imersão, entretanto, a sua ação antimicrobiana foi comprometida após inclusão nas resinas acrílicas.


Aim:To perform an in vitro evaluation of the activity of Staphylococcus aureus and Candida albicansin conventional prosthesis bases, based on methyl polymethylmethacrylate with silver nanoparticles incorporated into the composition. Methods: An experimental laboratory study was carried out using commercially available self-curing acrylic resins, Vipi Flash/VIPI and JET/Clássico. Eighty specimens were manufactured and divided into 16 groups (n = 5), referent to the resin brand, treatment (incorporation and immersion in the silver nanoparticle solution), and inoculated microorganism. The nanoparticles were synthesized with polymethacrylic acid and silver nitrate, and were irradiated with a low power (~ 8W) ultraviolet light for 6 hours. Their concentrations were idealized by the method of microplate dilution to determine the minimum inhibitory concentration when compared to the selected microorganisms. Bactericidal and fungicidal activities were identified with an initial concentration of 25% and a subsequent dilution factor of 12.5%. Results:It was difficult to incorporate the AgNPs into the acrylic resin, which may well have resulted from the change from the 3:1 proportion recommended by the manufacturer or by reducing or inactivating the action of the silver nanoparticle by interaction with polymethylmethacrylate. VIPI with the inclusion of nanoparticles obtained a lesser Candida albicans biofilm adherence. Conclusion: Silver nanoparticles were effective in controlling Candida albicans and Staphylococcus aureus in the immersion method; however, the antimicrobial activity was compromised after inclusion in acrylic resins.


Subject(s)
Silver Nitrate/pharmacology , Dental Prosthesis/microbiology , Polymethyl Methacrylate/pharmacology , Nanotechnology/methods , Nanoparticles/chemistry , Biological Control Agents/pharmacology , Staphylococcus aureus/drug effects , Candida albicans/drug effects , Anti-Infective Agents/pharmacology , Antifungal Agents/pharmacology
7.
Arq. bras. oftalmol ; 83(1): 62-64, Jan.-Feb. 2020. graf
Article in English | LILACS | ID: biblio-1088956

ABSTRACT

ABSTRACT We present a patient who underwent evisceration surgery after spontaneous rupture of the ocular globe due to long-data uncontrolled glaucoma, with posterior placement of an orbital implant made of a bone cement compound based on polymethylmethacrylate as alternative materials were not available. Such a compound is characterized by excellent biocompatibility and low cost, which makes it an interesting alternative for treatment. The anophthalmic socket was successfully filled, providing proper esthetic results and favorable conditions for the posterior scleral prosthesis implantation. No complications were observed during 10 months of follow-up. We believe that, in the absence of alternative materials, low-cost materials may be used in emergency settings to repair anophthalmic cavities and provide satisfactory functional and esthetic outcomes.


RESUMO Apresentamos um paciente que foi submetido à cirurgia de evisceração após ruptura espontânea do globo ocular devido a glaucoma não controlado de longa data, com posterior colocação de implante orbital feito de cimento ósseo, composto à base de polimetilmetacrilato, diante da indisponibilidade de materiais alternativos. Tal composto se caracteriza pela excelente biocompatibilidade e baixo custo, o que o torna uma alternativa interessante para o tratamento. A cavidade anoftálmica foi preenchida com sucesso, fornecendo resultados estéticos adequados e condições favoráveis para o implante posterior de prótese escleral. Nenhuma complicação foi observada durante os 10 meses de seguimento. Acredi­tamos que, na ausência de materiais alternativos, materiais de baixo custo podem ser usados em situações emergenciais para preencher cavidades anoftálmicas e prover resultados funcionais e estéticos satisfatórios.


Subject(s)
Humans , Male , Aged , Orbit/surgery , Bone Cements , Orbital Implants , Rupture, Spontaneous/surgery , Rupture, Spontaneous/etiology , Biocompatible Materials , Glaucoma/complications , Eye Evisceration , Plastic Surgery Procedures
8.
Rev. bras. cir. plást ; 34(1): 156-162, jan.-mar. 2019. ilus
Article in English, Portuguese | LILACS | ID: biblio-994624

ABSTRACT

Introdução: Os preenchedores permanentes, apesar de resultados duradouros, são verdadeiros problemas quando causam complicações. No Brasil, o PMMA é um produto aprovado pela Anvisa, mas seu uso extrapola suas indicações, levando a complicações graves. Há mais de uma década, existem recomendações sobre sua restrição, mas casos com consequências graves do seu uso irresponsável são atuais. Objetivo: Relatar complicação grave do uso irregular do PMMA e discutir a realidade brasileira atual baseado em determinações das entidades médicas, assim como dos órgãos reguladores. Métodos: É relatado um caso de necrose extensa da região glútea após a injeção de PMMA por profissional não qualificado e discutida a situação brasileira atual do produto com base nas entidades médicas e revisão da literatura do Brasil. Discussão: Apesar do esforço das entidades médicas, são inúmeros os casos de complicações agudas e crônicas relatados na literatura brasileira. No ano de 2016, foram registradas mais de 17 mil complicações relacionadas ao PMMA, mesmo assim, é difícil estabelecer dados epidemiológicos confiáveis, pois não há controle do número de aplicações, da qualidade do produto utilizado e da capacitação dos profissionais que o utilizam. Conclusão: No Brasil, há um número expressivo de procedimentos reparadores para correção de complicações decorrentes do uso do PMMA. A gravidade do caso relatado traz à tona a necessidade de combate à má prática por profissionais não capacitados, assim como um controle mais rigoroso da comercialização do produto por entidades reguladoras.(AU)


Introduction: Use of permanent fillers can lead to significant complications. In Brazil, polymethylmethacrylate (PMMA) is a product approved by the Agência Nacional de Vigilância Sanitária (ANVISA), but its use exceeds its indications, leading to serious complications. Recommendations for restricted use have been in place for more than a decade, but cases with serious consequences due to inappropriate use are still seen. Objective: To report a serious complication due to inappropriate use of PMMA and discuss the current status of PMMA use in Brazil based on recommendations of medical societies and regulatory agencies. Methods: This report describes a case of extensive necrosis of the gluteal region after injection of PMMA by a non-qualified practitioner; the report also reviews the literature on the current status of PMMA use in Brazil. Discussion: Despite the efforts of medical societies, acute and chronic complications are still reported in the Brazilian literature. In 2016, more than 17,000 PMMArelated complications were reported; nevertheless, reliable epidemiological data remain unavailable because the number of treatments, the quality of the product, and the training of practitioners remain unregulated. Conclusion: A significant number of repair procedures are performed in Brazil to correct complications resulting from the use of PMMA. The severity of the reported case highlights the need to combat bad practice by untrained professionals, as well as the need for greater control of PMMA marketing by regulatory agencies.(AU)


Subject(s)
Humans , Female , Adult , Polymethyl Methacrylate/analysis , Polymethyl Methacrylate/adverse effects , Plastic Surgery Procedures/adverse effects , Necrosis/diagnosis
9.
Acta ortop. bras ; 27(1): 55-58, Jan.-Feb. 2019. tab
Article in English | LILACS | ID: biblio-973597

ABSTRACT

ABSTRACT Objective: There is no consensus in the literature regarding the time taken to remove antibiotic spacers in the treatment of bone infections. The aim of this study is to evaluate the clinical results of patients with prolonged retention of the same. Methods: Patients selected were diagnosed with post-osteosynthesis infection and/or osteomyelitis and were submitted to treatment using an orthopedic cement spacer (polymethylmethacrylate) with vancomycin, retaining it for a period of more than 12 months. They were clinically evaluated to determine the presence of local or systemic infectious signs via hemogram, investigations of inflammatory markers, liver, renal and, with radiographic control. Results: Eighteen patients were included in the study. The mean retention time of the spacer was 30.4 months (15 - 61 months). No patient had clinical signs of local or systemic infectious relapse at the time of evaluation. Seven patients (39%) presented non-disabling pain in the operated limb. Seventeen patients (94%) presented a reduction in C-reactive protein values compared to the preoperative period. Radiographically, no migration, no spacer failure, or bone sequestration occurred. Conclusion: In this retrospective case series, cement spacer retention with vancomycin for more than 12 months was associated with good clinical results, without relapse of the infectious condition. Nível de Evidência IV. Estudos Terapêuticos - Investigação dos Resultados do Tratamento.


RESUMO Objetivos: Na literatura não há consenso em relação ao tempo para a retirada dos espaçadores com antibiótico no tratamento das infecções ósseas. O objetivo deste estudo é avaliar os resultados clínicos de pacientes com retenção prolongada dos mesmos. Métodos: Foram selecionados pacientes com infecção pós-osteossíntese e/ou osteomielite submetidos a colocação de espaçador de cimento ortopédico (polimetilmetacrilato) com vancomicina que retiveram o mesmo por período superior a 12 meses. Os pacientes foram avaliados clinicamente quanto à presença de sinais infecciosos locais ou sistêmicos, laboratorialmente com hemograma, marcadores inflamatórios, função hepática, renal e radiograficamente. Resultados: Dezoito pacientes foram incluídos no estudo. O tempo médio de retenção do espaçador foi de 30,4 meses (15 a 61 meses). Nenhum paciente apresentou sinais clínicos de recidiva infecciosa local ou sistêmica no momento da avaliação. Sete pacientes (39%) apresentaram dor não incapacitante no membro operado. Dezessete pacientes (94%) apresentaram redução nos valores da proteína C reativa comparativamente ao período pré-operatório. Radiograficamente, não houve migração, falha do espaçador ou identificação de sequestro ósseo em nenhum caso. Conclusão: Nessa série de casos retrospectiva, a retenção do espaçador de cimento com vancomicina por mais de 12 meses foi associada a bons resultados clínicos, sem recidiva do quadro infeccioso. Level of Evidence IV. Therapeutic Studies Investigating the Results of Treatment.

10.
ROBRAC ; 27(80): 24-29, jan./mar. 2018. ilus, tab
Article in English | LILACS | ID: biblio-906031

ABSTRACT

Objective: The aim of this study was to evaluate the effect of microwave-energy polymerization on the accuracy and glass transition temperature of acrylic resin denture bases submitted to reline procedure. As denture wearers make up a large portion of the population and often cannot afford a new complete denture, the reline procedure may be the best alternative when indicated. Thus, it is important to evaluate possible changes that would contraindicate this technique. Materials and methods: Twenty denture bases were fabricated from microwave-cured acrylic resin (Onda-Cryl) and randomly divided into control and test groups (n = 10). In the control group, the bases were submitted to measurement of misfit. Bases in the test group were worn down internally and relined. Misfit was measured by cutting the set stone cast/denture base at three predetermined points (canine, molar and tuberosity), measuring the gap between the stone cast and the acrylic resin base at three points using the ImageTool®software suite. Differential scanning calorimetry was used to determine Tg. Data were submitted to t-test for independent- samples (p<0.05). Results: The greatest misfit of canine sections was found at the midpoint of control group (0.280 mm); in molar sections, no significant difference was found. In maxillary tuberosity sections, the greatest misfit occurred at the midpoint of test group (0.352 mm). All gaps were below the maximal clinically acceptable misfit value. There was no significant difference in Tg values between groups. Conclusion: Microwave-energy processing does not affect the fit or Tg of relined denture bases.


Objetivo: Avaliar o efeito da polimerização utilizando energia de micro-ondas na adaptação e na temperatura de transição vítrea de bases de prótese submetidas ao procedimento de reembasamento. Uma vez que usuários de próteses totais constituem grande parte da população, o procedimento de reembasamento pode ser a melhor alternativa, quando indicado. Assim, se faz importante a avaliação de possíveis alterações que contraindicariam esta técnica. Materiais e Métodos: Foram confeccionadas 20 bases de prótese utilizando resina acrílica polimerizada por micro-ondas (Onda-Cryl) e divididas aleatoriamente em grupo controle e teste (n=10). No grupo controle as bases foram submetidas à mensuração da desadaptação. Já no grupo teste as bases foram desgastadas internamente e submetidas ao procedimento de reembasamento utilizando a mesma resina acrílica e a polimerização por energia de micro-ondas. A desadaptação foi mensurada por meio do corte do conjunto modelo de gesso/ base de prótese, em três pontos pré-determinados, em ambos os grupos. Cada área seccionada foi mensurada em três pontos, utilizando o programa ImageTool®software. O ensaio de calorimetria exploratória diferencial foi utilizado para determinar a Tg em ambos os grupos. Os dados foram submetidos ao teste t para amostras independentes (p<0,05). Resultados: No bloco de canino, a maior desadaptação foi observada no ponto mediano do grupo controle (0,280 mm); no bloco de molares não houve diferença estatística entre os grupos. Já na comparação dos blocos de tuber, a maior desadaptação ocorreu no ponto mediano do grupo teste (0,352 mm). Apesar dos valores de desadaptação encontrados, nenhum foi igual ou superior ao valor máximo aceito clinicamente. Conclusão: A polimerização utilizando energia de micro-ondas não afetou a adaptação ou a Tg das bases de prótese submetidas ao reembasamento.

11.
Rev. Col. Bras. Cir ; 44(2): 154-162, Mar.-Apr. 2017. tab, graf
Article in English | LILACS | ID: biblio-842659

ABSTRACT

ABSTRACT Objective: to present our experience in the surgical treatment of extensive skullcap defects with customized acrylic implants. Methods: we conducted a retrospective analysis of patients with extensive skull defects undergoing acrylic cranioplasties between 2004 and 2013. We carefully selected all patients and classified surgical results based on three scales (craniofacial esthetics, improvement of facial symmetry and need for additional surgery). Results: fifteen patients underwent cranioplasty with intraoperative acrylic implants, whether manually customized (46.67%) or made with prototyped three-dimensional biomodels (53.33%). There were two (13.33%) complications (one infection with implant withdrawal and one seroma). We considered the craniofacial aesthetics excellent (50%), the degree of improvement of craniofacial symmetry satisfactory (57.14%), and the overall mean of surgical results according to the need for new surgeries was 1.5±0.52. Conclusion: cranioplasties of patients with extensive skullcap defects should obey careful and predetermined criteria, both for selection and for the acrylic implant customization method.


RESUMO Objetivo: apresentar nossa experiência no tratamento cirúrgico dos defeitos extensos da calota craniana com implantes de acrílico customizados. Métodos: análise retrospectiva de pacientes com defeitos extensos da calota craniana submetidos à cranioplastias com acrílico entre 2004 e 2013. Todos os pacientes foram criteriosamente selecionados e os resultados cirúrgicos foram classificados com base em três escalas (estética craniofacial, melhora da simetria facial e necessidade de cirurgia adicional). Resultados: Quinze pacientes foram submetidos à cranioplastia com implantes de acrílico customizados manualmente no intraoperatório (46,67%) e confeccionados com base em biomodelos tridimensionais prototipados (53,33%). Mesmo respeitando critérios de seleção, houve duas (13,33%) complicações (infecção com retirada do implante e seroma). A estética craniofacial foi considerada excelente (50%), o grau de melhora da simetria craniofacial foi considerado satisfatório (57,14%) e a média global dos resultados cirúrgicos de acordo com a necessidade de novas cirurgias foi 1,5±0,52. Conclusão: as cranioplastias dos pacientes com defeitos da calota craniana extensos devem ser criteriosamente indicadas, obedecendo a critérios pré-determinados de seleção dos pacientes, bem como, do método de customização do implante de acrílico.


Subject(s)
Humans , Male , Female , Adult , Prostheses and Implants , Skull/surgery , Acrylic Resins , Patient Selection , Prosthesis Design , Retrospective Studies , Plastic Surgery Procedures/methods
12.
Geriatr., Gerontol. Aging (Online) ; 11(1): 42-47, jan.-mar. 2017. tab
Article in English, Portuguese | LILACS | ID: biblio-849238

ABSTRACT

Introduction: The population around the world is aging. With this, there will be an increased incidence of fractures due to osteoporosis of the hip and this will be a serious global health problem. A World Health Organization (WHO) estimate suggests that the incidence of hip osteoporotic fractures worldwide will triple by 2050. Objective: To present, through a literature review, the main results of the femoral reinforcement, a technique described by scientific articles, with the potential to increase the proximal femoral load for the occurrence of fractures, whether using polymethylmethacrylate (PMMA), phosphate cement calcium (CPC), elastomers and metal implants. Methods : Through electronic search in databases PubMed, Latin American and Caribbean Center of Health Information Information (Bireme), Coordination for the Improvement of Higher Education Personnel (Capes), Scientific Electronic Library Online (SciELO), Google Scholar And Cochrane, using the terms cementoplasty and femororplasty, the studies were selected according to a specific inclusion criterion, describing the main findings of the biomechanical results, type of study and material used to perform the femoral reinforcement. Results : Of the 15 articles analyzed, 14 were experimental analyzes and one was a clinical trial, seven studies used PMMA, two used CPC, four elastomers and two metal implants, 13 of them showed favorable Newton load (N) results for the fracture hip. Conclusion: Most of the studies on femoral reinforcement is experimental, and mostly used the PMMA, presenting an increase in the load in N for fracture occurrence.


Introdução: A população em todo o mundo está envelhecendo. Com isso, haverá aumento da incidência de fraturas por osteoporose do quadril e esse será um grave problema de saúde mundial. Uma previsão da Organização Mundial de Saúde (OMS) mostra que a incidência de fraturas osteoporóticas do quadril em todo o mundo triplicará até o ano 2050. Objetivo : Apresentar por meio de revisão da literatura os principais resultados do reforço femoral, técnica descrita por artigos científicos, com potencial de incrementar a carga do fêmur proximal para a ocorrência de fraturas, seja com uso de polimetilmetacrilato (PMMA), cimento fosfato de cálcio (CPC), elastômeros ou implantes metálicos. Métodos : Por meio de busca eletrônica nas bases de dados PubMed, Latin American and Caribbean Center of Health Science Information (Bireme), Coordination for the Improvement of Higher Education Personnel (Capes), Scientific Electronic Library Online (SciELO), Google Scholar and Cochrane, utilizando os termos Cementoplasty e femororplasty, foram selecionados os trabalhos respeitando um critério de inclusão específico, descrevendo os principais achados dos resultados biomecânicos, o tipo de estudo e o material utilizado na realização do reforço femoral. Resultados : Dos 15 artigos analisados, 14 são análises experimentais e um é ensaio clínico, sete estudos utilizaram PMMA, dois usaram CPC, quatro elastômeros e dois implantes metálicos, 13 deles mostram resultados favoráveis na carga em Newton (N) para a ocorrência da fratura do quadril. Conclusão: A maioria dos estudos sobre reforço femoral é experimental e em sua maioria utilizou o PMMA, apresentando incremento da carga em N para a ocorrência de fratura.


Subject(s)
Aged , Aged, 80 and over , Osteoporosis , Polymethyl Methacrylate , Osteoporotic Fractures , Hip Fractures , Review
13.
Surg. cosmet. dermatol. (Impr.) ; 8(4): 366-369, out.-dez. 2016. ilus
Article in English, Portuguese | LILACS | ID: biblio-877367

ABSTRACT

Substâncias para preenchimento têm sido muito utilizadas nos últimos anos em procedimentos estéticos e para correção de lipodistrofias em pacientes HIV-positivos. O granuloma de corpo estranho pode ser secundário à aplicação de produtos absorvíveis/temporários e mais frequentemente aos preenchedores inabsorvíveis/permanentes. Não é possível prever a formação desses granulomas que podem ocorrer independentemente da técnica utilizada. Neste artigo descreve-se o tratamento cirúrgico de uma paciente com múltiplos granulomas causados por preenchimento intradérmico prévio de PMMA na face, com resposta pobre a tratamentos conservadores, e com grave comprometimento psicossocial devido a essa complicação inestética e deformante.


Injectable fillers have long been used for cosmetic purposes and in HIV induced lipodystrophy patients. A foreign body granuloma may be a side effect of the application of absorbable products/temporary and most often the nonabsorbable/permanent fillers. It is not possible to predict the formation of these granulomas, and it may occur regardless of the application technique. In this article we describe the surgical treatment of a patient with multiple granulomas caused by intradermal injection of PMMA in the face, with poor response to conservative treatments, and severe psychosocial impairment due to this unsightly and disfiguring complication.

15.
ACM arq. catarin. med ; 44(1): 93-105, jan. - mar. 2015. Tab
Article in Portuguese | LILACS | ID: biblio-1869

ABSTRACT

Objetivos: Identificar fatores associados ao uso do polimetilmetacrilato em pacientes HIV positivos sob tratamento antirretroviral em Santa Catarina e definir o perfil dos pacientes que buscam o tratamento para lipoatrofia facial. Métodos: Estudo transversal com 219 pacientes elaborado a partir de registros no SINAN (Sistema de Informação de Agravos de Notificação) e concomitantemente no serviço realizador da intervenção para lipoatrofia facial no âmbito do Sistema Único de Saúde no Estado de Santa Catarina, no período de 2008 a 2011, em que foram avaliados possíveis fatores de risco em variáveis sóciodemográficas e clínicas relacionadas à doença e à intervenção. Resultados: Os pacientes tinham em média 48 anos variando de 30 a 74 anos, sendo predominantemente do sexo masculino (70,8%). Foi encontrada associação significativa entre hipertensão arterial sistêmica (p=0,0006), sexo masculino (p=0,0010), realização de transfusão sanguínea (p=0,013), pacientes não etilistas (p=0,014) e portadores de HIV há mais de 5 anos (p=0,049) e a maior aplicação de polimetilmetacrilato. Em média, o grupo homossexual necessitou de quase 0,6 intervenções a mais do que o grupo heterossexual para uso de metacrilato, assim como maior volume (6,16mL). Conclusão: Pacientes do sexo masculino, homossexuais, hipertensos, que realizaram transfusão sanguínea, não etilistas e que possuem diagnóstico da doença há mais de 5 anos fizeram aplicação de maior volume de polimetilmetacrilato.


Objectives: Identify factors associated with use of polymethylmetacrylate HIV-infected patients in with treatment on antiretroviral in Santa Catarina and define the profile of patients seeking treatment for lipoatrophy. Methods: Cross-sectional study with 219 patients compiled from records in SINAN (Information System for Notifiable Diseases) and concurrently director of the service intervention for facial lipoatrophy in the SUS in the state of Santa Catarina, from 2008 to 2011, where they were assessed possible risk factors in clinical and sociodemographic variables related to illness and intervention. Results: Patients had an mean of 48 years ranging from 30 to 74 years, predominantly male (70.8%). There was use of higher volume of polymethyl methacrylate in the face of patients with hypertension (p = 0.0006), male gender (p = 0.0010), performance of blood transfusion (p = 0.013), non-alcoholic patients (p = 0.014) and HIV for over 5 years (p = 0.049). On mean, the homosexual group interventions needed almost 0.6 more than the heterosexual group for use methacrylate as well as higher volume (6.16 mL). Conclusion: Homossexual men, hypertensive, patients who underwent blood transfusion, nondrinkers as well as who have a diagnosis of the disease for more than 5 years showed increased risk for higher volume of polymethyl methacrylate in the face male patients.

16.
RFO UPF ; 19(2): 166-171, maio/agosto 2014.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-737234

ABSTRACT

Objetivo: o presente estudo tem por objetivo avaliar a influência da adição de diferentes concentrações de subnitrato de bismuto (SN) nas propriedades de mate-riais para base protética. Materias e método: foi adicio-nada 0%, 1%, 2%, 5%, 10% e 20% de SN em peso em resina acrílica autopolimerizável da marca Clássico e submetidos aos ensaios de resistência à flexão, micro-dureza Knoop, radiopacidade, análise antimicrobiana, rugosidade e caracterização em micro-Raman. O teste estatístico escolhido foram o ANOVA de uma via e o teste de comparações múltiplas de Tukey. O nível de significância foi de 5% para todos os testes. Resultados: os resultados de resistência à flexão atingiram valores acima do recomendado pela ISO 1567. Quanto maior a concentração da carga de SN maior o valor de mi-crodureza Knoop, sendo estatisticamente significativo em 10% e 20% (p<0,001); os resultados da rugosidade mostraram valores abaixo do limiar, 0,2 µm. A adição de subnitrato de bismuto não obteve um potencial an-timicrobiano, mas apresentou uma maior radiopacida-de, (p<0,001). Conclusão: diante dos dados, conclui-se que a adição da carga de SN influencia nas proprie-dades mecânicas de resina acrílica significativamente, destacando-se que a radiopacidade desse material faci-lita a sua remoção quando ingerida ou aspirada.

17.
ROBRAC ; 23(65)jul 2014. ilus
Article in Portuguese | LILACS | ID: lil-763975

ABSTRACT

Objetivo: este artigo relata uma técnica de reabilitação por prótese nasal constituída externamente por uma camada de silicone aderida a uma base de resina acrílica. Material e método: o paciente J.A. de 62 anos apresentava perda da estrutura externa do nariz por carcinoma espinocelular. Após moldagem e obtenção do modelo facial, foi feito o enceramento da prótese nasal. O modelo do nariz em cera, após ter sido remodelado no paciente, foi duplicado e um dos modelos incluído em mufla para microondas para eliminação da cera e polimerização da peça em resina acrílica com pigmentação intrínseca. Esta foi reduzida em espessurae realizadas perfurações que serviram de retenção para o silicone que recobriu toda a porção externa da peça. O silicone foi pigmentado e manipulado após seleção prévia da cor da pele do paciente. Depois foi inserido sobre a resina e incluído na mufla, e polimerizado sob pressão em prensa de bancada durante 24 horas. A prótese polimerizada foi provada no paciente, corrigida quanto à caracterização de cor, e após sua aprovação, foi fixada à pele por meio de adesivo à base de hidroxipropil celulose. O paciente foi orientado quanto à higiene diária da prótese e retornou em sessões sucessivas para proservação. Conclusão: a prótese nasal com base interna de resina e superfície externa de silicone, fixada com adesivo a base de hidroxipropil celulose admitiu bons resultados estéticos e boa qualidade.


Purpose: this article reports a technique of rehabilitation with nasal prosthesis made by a layer of silicone and acrylic resin. Material and methods: the patient J.A.S., 62 years old, had his nose lost in order to remove a squamous cell carcinoma. After getting the facial model, the nasal prosthesis was waxed. After being refurbished in the patient, the wax model was duplicated and one of the models was included in microwave oven for removal of wax and polymerization of the acrylic resin base with intrinsic pigmentation. The base thickness was reduced and retention holes were made to retain the silicone that recovered theentire external surface. The silicone was pigmented and manipulatedaccording to the patient?s skin color. The silicone was added over the acrylic resin base and the set was flasked and cured under pressure in a bench press for 24 hours. After color and adaptation adjustments, the nasal prosthesis was fixed to the skin with hydroxypropyl cellulose based adhesive. The patient was instructed to clean the prosthesis daily and to return to successive proservation sessions. Conclusion: the nasal prosthesis made with inner bases of resin and external surface ofsilicone fixed with adhesive admitted esthetic results and great quality.

18.
Rev. cir. traumatol. buco-maxilo-fac ; 14(2): 19-23, Abr.-Jun. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-792325

ABSTRACT

O complexo maxilofacial possui função protetora para o neurocrânio e torna-se conseqüente alvo dos traumas envolvendo a região. As fraturas faciais podem acarretar seqüelas, assimetrias e defeitos estéticos, e a utilização de enxertos autógenos nem sempre é possível. Dentre os materiais aloplásticos, o implante de polimetilmetacrilato é uma resina de base acrílica considerada uma boa opção para reconstrução de defeitos ósseos faciais por possuir baixo custo, ser inerte, biotolerado, diminuir o tempo cirúrgico, e permite fácil manipulação e modelagem. O presente artigo tem como objetivo discutir as indicações, vantagens e desvantagens do uso do polimetilmetacrilato no tratamento facial pós-traumático através de um relato de caso clínico... (AU)


The maxillofacial complex protects the neurocranium and becomes the target of subsequent trauma involving the region. Facial fractures can cause sequelae, asymmetry and aesthetic faults, and the use of autogenous grafts sometimes is not possible. Among the alloplastic grafts, polymethylmethacrylate is an acrylic based resin considered a good option for reconstruction of facial bone defects by having low cost, being inert and tolerable, and decreasing surgical time and be easily manipulated or molded. This article aims to discuss the use, advantages and disadvantages of the use of polymethylmethacrylate in posttraumatic facial treatment using a clinical case report... (AU)


Subject(s)
Humans , Male , Adult , Polymethyl Methacrylate , Plastic Surgery Procedures , Facial Bones , Facial Bones/surgery
19.
Arq. bras. oftalmol ; 77(2): 71-75, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-716265

ABSTRACT

Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL) in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR) was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC) was -2.19 (SD: ± 0.53). After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001). Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence. .


Objetivo: Avaliar o resultado pós-operatório de uma nova lente intraocular (LIO) multifocal tórica implantada em pacientes com catarata e astigmatismo corneano. Métodos: Estudo prospectivo não randomizado envolvendo pacientes com catarata, astigmatismo corneano, e motivação para eliminar a dependência dos óculos. Em todos os casos, a lente intraocular tórica Rayner M-flex® T foi implantada dentro do saco capsular. Três meses pós-operatório foram avaliados: acuidade visual para longe, intermediário e perto; equivalente esférico; astigmatismo refracional residual; curva de defocus e sensibilidade ao contraste. Ao final do estudo um questionário referente à satisfação visual foi aplicado. Resultados: Trinta e quatro olhos de 18 pacientes foram incluídos no estudo. Após 3 meses de pós-operatório, a acuidade visual corrigida para longe (logMAR) era de 0,00 ± 0,08 a 6 m, 0,20 ± 0,09 a 70 cm e 0,08 ± 0,11 a 40 cm. A acuidade visual sem correcão foi de 20/40, ou melhor, em 100% dos olhos. A média do cilindro refracional pré-operatório era de -2,19 (DP: ± 0,53). Após o seguimento de 3 meses a média do cilindro refracional era de -0,44 D (DP: ± 0,27) (p<0,001). Os níveis de sensibilidade ao contraste foram elevados. Ao final do seguimento, 87,5% dos pacientes estavam independentes dos óculos para perto, intermediário e para longe, e aproximadamente 44% dos pacientes relatavam halos e glare. Conclusão: O implante de uma lente intraocular multifocal em pacientes com catarata e astigmatismo corneano utilizando a lente intraocular tórica Rayner M-flex® T foi uma opção simples, segura e acurada. Essa nova tecnologia oferece ao cirurgião uma maneira passível de se atingir as expectativas dos pacientes em relação ...


Subject(s)
Aged , Female , Humans , Male , Astigmatism/surgery , Cataract Extraction/methods , Cataract/complications , Lenses, Intraocular , Lens Implantation, Intraocular/methods , Astigmatism/complications , Cataract/physiopathology , Contrast Sensitivity/physiology , Patient Satisfaction , Prospective Studies , Treatment Outcome , Visual Acuity/physiology
20.
Rev. odontol. UNESP (Online) ; 42(3): 196-203, maio-jun. 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-678423

ABSTRACT

Introdução: A estabilidade dimensional das resinas acrílicas influencia na adaptação das coroas provisórias e, consequentemente, no resultado do tratamento reabilitador. Objetivo: Avaliar a estabilidade dimensional, ao longo do tempo, de uma resina acrílica processada de diferentes maneiras. Material e Método: Cinco técnicas de polimerização da resina acrílica foram testadas: I - polimerização térmica utilizando líquido de polimerização rápida em mufla; II - autopolimerização sob pressão; III - autopolimerização utilizando pincel; IV - autopolimerização após mistura (pó + líquido) em pote Dappen e inserção em matriz de aço na fase arenosa; V - autopolimerização após mistura em pote Dappen com inserção na matriz metálica na fase plástica. Foram confeccionados dez corpos de prova para cada tipo de processamento. Avaliou-se a estabilidade dimensional por meio de matriz de aço inox confeccionada segundo a especificação nº19 da ADA. Os corpos de prova foram armazenados em água destilada a 37ºC e examinados nos períodos de 1 hora, 1, 7, 15, 10, 90 e 180 dias após a polimerização, com o auxílio de um microscópio óptico com aumento de 20×. Os resultados foram submetidos à análise de dupla variância (Teste de Tukey para Tempo e Técnica de processamento) em nível de 5% de significância. Resultado: Todos os grupos experimentais apresentaram alterações dimensionais entre o sétimo e o 15º dia; após esse período de tempo, houve alterações dimensionais estatisticamente significantes, para as diferentes técnicas estudadas. Conclusão: A estabilidade dimensional da resina acrílica não sofreu influência das diferentes técnicas de processamento avaliadas; entretanto, foi influenciada pelo tempo de armazenamento.


Introduction: The dimensional stability of acrylic resins influences the temporary crowns fitting and can affect the final restoration results. Objective: To evaluate the long-term dimensional stability of an acrylic resin used for fabrication of provisional crowns. Material and Method: Five types of processing techniques were evaluated: I - thermal polymerization using fast polymerization liquid and flask; II - auto-polimerization under pressure in a stainless steel matrix; III - auto-polimerization using the bead brush technique to build the sample; IV - auto-polimerization after mixture (powder + liquid) in a dappen dish and insertion in a stainless steel matrix at the sand stage; V - auto-polimerization after mixture in a dappen dish with insertion in a stainless steel matrix at the plastic stage. For each type of processing technique, 10 samples were made. Dimensional stability was evaluated by means of a steel matrix made following the ADA specification nº19. The samples were stored in distilled water at 37 ºC and examined at the periods of 1 hour, 1, 7, 15, 30, 90 and 180 days, with an optic microscope with 20× magnification. The results were subjected to the 2-way analysis of variance (Tukey Test) at the significance level of 5% for the variables Time and Processing Technique. Result: All samples had dimensional alterations from day 7 to the day 15, regardless of the technique used. From day 15 to 180, there were no statistically significant dimensional alterations. Conclusion: The dimensional stability of the acrylic resin was not influenced by the different processing techniques tested, however, it was influenced by the storage time.


Subject(s)
Acrylic Resins , Dental Marginal Adaptation , Polymethyl Methacrylate , Crowns , Dental Restoration, Temporary , Denture, Partial, Fixed , Analysis of Variance , Data Interpretation, Statistical , Microscopy
SELECTION OF CITATIONS
SEARCH DETAIL